in General Tech Discussion
8 years ago
I installed a new LiFeP04 in my REMOS (912 ULS) and a Voltage Limiter (VL) to protect the battery from high voltage ( a REMOS requirement SB-013). After 10 minutes of flight the VL trips. I've measured voltage at the battery and it is a steady 13.6 volts until 10 or 12 minutes when I observe it creeping up to 15 volts and the VL trips. After I land, shut down and immediately restart the VL is reset and after a few minutes of flying it happens again. Any ideas? The Voltage Regulator is a 4 year old Schicke GR6.
-
Roger Lee
LSRM-A & Rotax Instructor & Rotax IRC
Tucson, AZ Ryan Airfield (KRYN)
520-349-7056 Cell
-
-
Thank you said by: ERNEST BITTEN
-
-